Condition |
Possible cause |
Correction / reference item |
Generator does not charge | Open- or short-circuited lead wires, or loose lead connections. | Repair, replace or connect properly. |
Short-circuited, grounded or open generator coil. | Replace | |
Short-circuited or punctured regulator/ rectifier. | Replace | |
Generator does charge, but charging rate is below the specification | Lead wires tend to get short- or opencircuited or loosely connected at terminals. | Repair or retighten. |
Grounded or open-circuited generator coil. | Replace | |
Defective regulator/rectifier | Replace | |
Defective cell plates in the battery. | Replace the battery | |
Generator overcharges | Internal short-circuit in the battery. | Replace the battery |
Damaged or defective regulator/rectifier | Replace | |
Poorly grounded regulator/rectifier | Clean and tighten ground connection. | |
Unstable charging | Lead wire insulation frayed due to vibration, resulting in intermittent shortcircuiting. | Repair or replace |
Internally short-circuited generator. | Replace | |
Defective regulator/rectifier | Replace | |
Battery overcharges | Faulty regulator/rectifier. | Replace. |
Faulty battery | Replace. | |
Poor contact of generator lead wire coupler. | Repair. | |
Battery runs down quickly | Trouble in charging system | Check the generator, regulator/rectifier and circuit connections and make necessary adjustments to obtain specified charging operation. |
Cell plates have lost much of their active materials a result of overcharging | Replace the battery and correct the charging system. | |
Internal short-circuit in the battery | Replace the battery | |
Too low battery voltage. | Recharge the battery fully. | |
Too old battery. | Replace the battery. | |
Battery “sulfation” | Incorrect charging rate. (When not in use battery should be checked at least once a month to avoid sulfation.) | Replace the battery |
The battery was left unused in a cold climate for too long. | Replace the battery if badly sulfated |
Drive chain cleaning and
oiling
Clean and oil the chain as follows:
Wash the chain with kerosene.
Kerosene will lubricate and
clean the chain.
Warning
Kerosene can be hazardous .
Kerosene is flammable. Children
or pets may be harmed
from contact with kerosene.
Keep flames and smoking
mater ...
Engine stop switch inspection
Inspect the engine stop switch in the following
procedures:
turn the ignition switch off.
Remove the air cleaner box. Refer to “air cleaner box removal and
installation” in section 1d .
Disconnect the right handlebar switch coupler (1).
Inspect the engine stop ...
Diagnostic information and procedures
Drive chain and sprocket symptom diagnosis
Condition
Possible cause
Correction / reference item
Noisy drive chain
Worn sprocket
Replace
Worn drive chain
Replace
Stretched drive chain
Replace
Too large drive chain slack
Adju ...