Detected condition and possible cause
Detected condition |
Possible cause |
Pair control solenoid valve voltage is not input to ecm |
|
Wiring diagram
Troubleshooting
Caution when using the multi-circuit tester, do not strongly touch the terminal of the ecm coupler with a needle pointed tester probe to prevent terminal damage. |
Note after repairing the trouble, clear the dtc using sds tool. Refer to “use of sds diagnosis reset procedures” . |
Step |
Action |
Yes |
No |
1 |
Special tool Tester knob indication resistance (Ω) Pair control solenoid valve resistance 20 – 24 Ω at 20 – 30 °c (68 – 86 °f) (terminal – terminal) Is the resistance ok? |
Go to step 2. | Replace the pair control solenoid valve with a new one. Refer to “pair control solenoid valve removal and installation” in section 1b . |
2 |
Special tool Tester knob indication voltage ( ) Pair control solenoid valve voltage battery voltage ((+) terminal: o/w – (–) terminal: ground) Is the voltage ok? |
|
Open or short circuit in the o/w wire. |
Active control inspection
Malfunction code and defective condition table
* : Immobilizer system equipped model only. ...
Self-diagnosis function
The self-diagnosis function is incorporated in the ecm. The function has two
modes, “user mode” and “dealer mode”.
The user can only be notified by the lcd (display) panel and led (fi indicator
light). To check the function of the
individual fi system devices, the dealer mode is provided. In ...