Removal
Special tool (a): 09930–44530 (rotor holder)
Special tool
(b): 09930–30460 (rotor remover
bolt)
(c): 09930–34970 (rotor remover)
Installation
Install the generator in the reverse order of removal. Pay attention to the following points:
Tightening torque generator stator set bolt (a): 11 n·m (1.1 Kgf-m, 8.0 Lbf-ft) generator lead wire set bolt (b): 5.5 N·m (0.55 Kgfm, 4.0 Lbf-ft)
: Sealant 99000–31140 (suzuki
bond
no.1207B or equivalent)
Caution dry these parts naturally. Do not wipe them with a cloth or use compressed air to dry. |
Special tool (a): 09930–44530 (rotor holder)
Tightening torque generator rotor bolt (c): 145 n·m (14.5 Kgf-m, 105.0 Lbf-ft)
: Sealant 99000–31140 (suzuki
bond
no.1207B or equivalent)
Caution use new gasket to prevent oil leakage. |
Be careful
not to pinch the finger between the generator cover and crankcase. |
Note fit the clamp to the generator cover bolt “c”. |
Fail-safe function table
Fi system is provided with fail-safe function to allow the engine to start
and the motorcycle to run in a minimum
performance necessary even under malfunction condition.
The engine can start and can run even if the signal in the table is not
received from each sensor. But, the engine
...
Radiator reservoir tank inspection
Inspect the radiator reservoir tank in the following
procedures:
remove the right side cowling. Refer to “exterior parts removal and
installation” in section 9d .
Inspect the radiator reservoir tank (1) for leaks. If any
defects are found, replace the radiator reservoir tank
...
Excva removal and installation
Removal
Turn the ignition switch off.
Remove the left side cowling. Refer to “exterior parts removal and
installation” in section 9d .
Connect the special tool (mode select switch) to the dealer mode
coupler. Refer to “self-diagnostic procedures” in section 1a .
After tur ...