Seat ...
DTC “c62” (p0443): evap system purge
control solenoid valve circuit malfunction
(e-33 only)
Detected condition and possible cause
Detected condition
Possible cause
Evap system purge control valve voltage is not input to
ecm.
Evap system purge control valve circuit open or short.
Evap system purge control valve malfunction.
Ecm malfunction. ...