Service data
Fi sensors

Tightening torque specifications

Reference
: for the tightening torque of fastener not specified in this section, refer to “tightening torque list” in section 0c .
Isc valve preset and opening initialization
Special tools and equipmentDTC “c41” (p0230-h/l): fp relay circuit
malfunction
Detected condition and possible cause
Detected condition
Possible cause
C41
No voltage is applied to fuel pump.
Fuel pump relay circuit open or short.
Fuel pump relay malfunction.
Fuel pump relay switch circuit is shorted to power
source.
...
Exhaust control valve inspection
Inspect exhaust control valve
initially at 1 000 km (600 miles, 2 months) and every
12 000 km (7 500 miles, 24 months) thereafter
Inspect exhaust control valve as follows:
remove the left side cowling. Refer to “exterior parts removal and
installation” in section 9d .
Check t ...
Front wheel components
Front axle
Brake disc bolt
Brake disc
Dust seal
Bearing
Spacer
Air valve
Front wheel
Wheel balancer
Front tire
Collar
Front axle bolt
18 N·m (1.8 Kgf-m,
13.0 Lbf-ft)
100 N·m
(10.0 Kgf-m, 72.5 Lbf-ft)
Apply ...