Headlight removal and installationCharging system symptom diagnosis
Condition
Possible cause
Correction / reference item
Generator does not
charge
Open- or short-circuited lead wires, or
loose lead connections.
Repair, replace or connect properly.
Short-circuited, grounded or open
generator coil.
Replace
...
Brakes
This motorcycle has front and
rear disk brakes.
Warning
Failure to inspect and properly
maintain the brakes increases
your chance of having an accident.
Inspect the brake system
before each use according to
the inspection before
riding section. Follow the
maintenance ...
Dtc “c36” (p1764), “c37” (p1765), “c38” (p1766) or “c39” (p1767): secondary
fuel injector circuit
malfunction
Detected condition and possible cause
Detected condition
Possible cause
Some failure exists in the fuel injector signal in a high
load, high revolution condition.
Injector circuit open or short.
Injector malfunction.
Ecm malfunction.
...