Special tools and equipmentDTC “c22” (p1450-h/l): ap sensor circuit
malfunction
Detected condition and possible cause
Detected condition
Possible cause
C22
Ap sensor voltage is not within the
following range.
0.5 V ≤ Sensor voltage < 4.85 V
Note
note that atmospheric pressure
varies depending on weather
co ...
Cooling fan inspection
Cooling fan operating temperature
standard
(on → off): approx. 100 ?‹C (212 ƒ‹f)
(off → on): approx. 105 ?‹C (221 ƒ‹f)
Inspect the cooling fan in the following procedures:
disconnect the cooling fan motor coupler (1).
Test the cooling fan motor for load ...
Excva removal and installation
Removal
Turn the ignition switch off.
Remove the left side cowling. Refer to “exterior parts removal and
installation” in section 9d .
Connect the special tool (mode select switch) to the dealer mode
coupler. Refer to “self-diagnostic procedures” in section 1a .
After tur ...