Corrosion prevention
Washing the motorcycleRadiator reservoir tank inspection
Inspect the radiator reservoir tank in the following
procedures:
remove the right side cowling. Refer to “exterior parts removal and
installation” in section 9d .
Inspect the radiator reservoir tank (1) for leaks. If any
defects are found, replace the radiator reservoir tank
...
Dtc “c36” (p1764), “c37” (p1765), “c38” (p1766) or “c39” (p1767): secondary
fuel injector circuit
malfunction
Detected condition and possible cause
Detected condition
Possible cause
Some failure exists in the fuel injector signal in a high
load, high revolution condition.
Injector circuit open or short.
Injector malfunction.
Ecm malfunction.
...
DTC “c42” (p1650): ig switch circuit
malfunction
Detected condition and possible cause
Detected condition
Possible cause
Ignition switch signal is not input to the ecm.
Ignition system circuit open or short.
Ecm malfunction.
When the id agreement is not verified.
Ecm does not re ...