If the fuel level indicator light (1) does not function properly, check the fuel level gauge and its lead wire/ coupler.
If the fuel level gauge and its lead wire/coupler are functioning properly, replace the combination meter with a new one.

Engine coolant temperature indicator light inspection
Fuel level gauge inspectionFront fork parts inspection
Refer to “front fork disassembly and assembly” .
Inner and outer tubes
Inspect the inner tube and outer tube for scratches
Slide bushing / guide bushing
Inspect the slide bushing and guide bushing for wear or
damage. If they are worn or damaged, replace them with
new ones. If they are not ...
DTC “c12” (p0335): ckp sensor circuit
malfunction.
Detected condition and possible cause
Detected condition
Possible cause
The signal does not reach ecm for 3 sec. Or more, after
receiving the starter signal.
Metal particles or foreign material being stuck on the
ckp sensor and rotor tip.
Ckp ...
Cooling fan relay inspection
Inspect the fan relay in the following procedures:
remove the frame covers. Refer to “exterior parts
removal and installation” in section 9d (page 9d-
6).
Remove the cooling fan relay (1).
First check the insulation between “a” and “b”
terminals with tester. Then ap ...