Battery runs down quickly
Battery current leakage inspectionDTC “c40” (p0505 / p0506 / p0507): isc
valve circuit malfunction
Detected condition and possible cause
Detected condition
Possible cause
C40/P0505
The circuit voltage of motor drive is
unusual.
Isc valve circuit open or shorted to ground.
Air passage clogged.
Isc valve is fixed.
Isc valve prese ...
Charging system symptom diagnosis
Condition
Possible cause
Correction / reference item
Generator does not
charge
Open- or short-circuited lead wires, or
loose lead connections.
Repair, replace or connect properly.
Short-circuited, grounded or open
generator coil.
Replace
...
Starter relay inspection
Inspect the starter relay in the following procedures:
remove the starter relay. Refer to “starter relay removal and
installation” .
Apply 12 v to “a” and “b” terminals and check for
continuity between the positive and negative
terminals using the multi-circuit tester. If th ...